We make panels which match perfect with your requirement. We design for best performance and trouble free operation.
General Specification:
- Conforming to various standards
- Designing and manufacturing of the panels by considering most economy and best quality.
- Resistance of the panels against hard or improper environment
- The cubicles are designed and manufactured according to according to standards
- Front and rear accessibility to the equipments
- Allocation of suitable space for various compartments
- Installation of gland plate for the cables
- Powder Coated
Microprocessor Based Power Factor Controller:
- State of the art of microcontroller based compact design (By considering your load parameters)
- User Friendly operations
- Power Factor as well frequency indication.
- 3 mm LED indications for operator interaction.
- Self calibration for power factor and frequency.
- Membrane keyboard with tectile feedback to enter the set points for power factor ,dead band, sequence relay.
- Built in Auto / Manual function no need to install separate auto / manual switch
- Test mode to check the unit operation.
- Protection against spurious signal and surges.
- Cyclic switching of capacitor banks to optimise the life of capacitors.
- Under current locking for no loads during holidays or better for factories where operation is for 12 hours or daytime only.
- Over Voltage locking to safeguard capacitors.
Suitable for every application water, oil, Liquid, we provide different type of level sensor to suit your application.
For energy saving in cooling towers.
Most of woven sacks industries use cooling tower with fan or with water spray pumps .All cooling towers are designed
by considering operate when atmospheric temperature is too high such as in month of May And June but when atmospheric
temperature is low or at different line speed or in winter season or in rainy season (night) and sometime suddenly
weather changes water temperature becomes lower and plant operator reduces water inlet to quenching tank to maintain
temperature required for film. Normally it is done by half closing gate valve which forces to operate pump at more load,
which consumes more power.
It is better to switch off fan or water spray pump and switch on when temperature rises more than requirement.
We have designed our controller to do this automatically and record hours of switched off fan or water spray pump.
In case of air intake it automatically switches off water pump. It is observed that automatic switching off by controller
occurs 8 to 12 hours in winter, 2 to 6 hours in spring, 4 to 8 hours in rainy and 0 to 2 hours in summer.
Pay back period is 1 to 3 months.
This software is designed to monitor how efficiently power is utilized? It let's you know
what is actual cost per kg (or production), what is unit per kg (or production). How efficiently your D.G. Set is
operated.
When and what amount of your Demand is Jumped? What amount of rebate you can get and what amount you are getting?
You can also forecast your electricity bill for financial planning or you can check and verify your bill also.
Other important data which you get are - Duration of power supply from SEB and D.G. Set, P.F., Maximum Demand date-wise,
month-wise and year-wise.
Remarks you will get:
- Please check Fuel Consumption
- Load Percentage of D G Set
- Please check your capacitor panel
- Please Do not run D.G. set (when correct supply is available)
- You operated you plant efficiently / inefficiently
- You operated your D.G. Set efficiently / inefficiently.
It will guide you when, How and what to do to cut the cost of power with the help of energy management tools. It will require just 20 minutes for data
entry and report printing daily.
It gives alarm contact (potential free) when voltage at individual phase goes high or low at programmed value and phase sequence reversal.
It gives alarm contact (potential free) when P.F. goes high or low at programmed value.
|